. Keyed to match AUTOPULSE control units Applications The Electric Manual Pull Station is a cost-effective, feature-packed, non-coded manual fire alarm pull station. It was designed to meet multiple applications with the installer and end-user in mind. The pull station provides the AUTOPULSE control panels with an alarm initiating input signal. Ansul IQ-318 Panel The AUTOPULSE® IQ-318 intelligent Fire Alarm Control Panel is part of the AUTOPULSE Series of Fire Alarm Controls from ANSUL®. Designed with modularity and for ease of system planning, the AUTOPULSE IQ-318 can be configured with just a few devices for small building applications, or for a large campus or high-rise application.

  1. Ansul Autopulse 442r Manual
  2. Ansul Autopulse 442r Operation Manual Pdf
  1. (DACT), the installation and operation of the equipment and devices shall comply with 3RCNY §17-01. It shall have the capability of transmitting separate and distinct signals to indicate manual pull station alarm, automatic detection alarm, sprinkler waterflow alarm, supervisory signal indications and trouble indications.
  2. Ansul Maintenance And Operations Manual 31274 ANSUL SENTRY Water Model SY-0262 Extinguisher Assembly, Operation, Recharge, Inspection and Maintenance Manual, ANSUL Manual Monitor/Nozzle, High-Flow Series Model FJM-80 Data/Specifications Sheet (Rev. 06), ANSUL Remote Hose Reel Assemblies with Manual Rewind Large Dry Chemical Data Sheet (Rev.
Ansul

Ansul Autopulse 442r Manual

Autopulse 542 Panel

The AUTOPULSE® 542R is a six zone FACP for single and dual hazard agent releasing applications. Badan pe sitare lapete hue free mp3 songspk. The AUTOPULSE 542R provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. The AUTOPULSE 542R is compatible with System Sensor’s i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 45 °F (7.22 °C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to Device Compatibility Document for a complete listing of compatible devices.Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The AUTOPULSE 542R supervises all wiring, AC voltage, battery charger and battery level.

Activation of a compatible smoke detector or any normally open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel’s LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function.The AUTOPULSE 542R(E) releasing panel offers the same features as the AUTOPULSE 542R but allows connection to 220/240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 110/120 VAC and 220/240 VAC versions of the panels.

Ansul IQ-318 Panel

The AUTOPULSE® IQ-318 intelligent Fire Alarm Control Panel is part of the AUTOPULSE Series of Fire Alarm Controls from ANSUL®. Toyota employee lease program. Designed with modularity and for ease of system planning, the AUTOPULSE IQ-318 can be configured with just a few devices for small building applications, or for a large campus or high-rise application.

Autopulse

Simply add additional peripheral equipment to suit the application.

Mini-Bulk Low Pressure C02 Systems

Ansul Autopulse 442r Operation Manual Pdf

  • Listed to UL Standard 864, 9th edition
  • One isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7
  • Up to 159 detectors (any mix of ion, photo, thermal, or multi-sensor) and 159 modules (NO manual stations, two wire smoke, notification, or relay). 318 devices maximum
  • Standard 80-character display
  • 6.0 amp power supply with four Class A/B built-in Notification
  • Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization
  • Built-in Alarm, Trouble, and Supervisory relays
  • VeriFire® Tools offline program option. Sort Maintenance Reports by compensation value (dirty detector), peak alarm value, or address
  • Autoprogramming and Walk Test reports
  • Optional universal 318-point DACT
  • 80-character remote annunciators (up to 32)
  • EIA-485 annunciators, including custom graphics
  • Printer interface (80-column and 40-column printers)
  • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file
  • Alarm Verification selection per point, with tally
  • Autoprogramming and Walk Test reports
  • Positive Alarm Sequence (PAS) Presignal
  • Silence inhibit and Auto Silence timer options
  • March time / temporal / California two-stage coding / strobe synchronization
  • Field-programmable on panel or on PC, with VeriFire Tools program check, compare, simulate
  • Full QWERTY keypad
  • Charger for up to 90 hours of standby power
  • Non-alarm points for lower priority functions
  • Remote ACK/Signal Silence/System Reset/Drill via monitor modules
  • Automatic time control functions, with holiday exceptions
  • Surface Mount Technology (SMT) electronics
  • Extensive, built-in transient protection
  • Powerful Boolean logic equations